Product DescriptionCJX2 series AC Contactor is suitable for using the circuit up to the rated voltage 660V AC 50Hz or 60Hz, rated current up to 1000A, for making, breaking, frequently starting&controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter, With the thermal relay. It is combined into the electromagnetic starter. The Contactor is produced according to IEC60947-4 and GB14048.4.
Product Specification
Type |
Rated heat current (A) |
Rated working current (A) |
AC3 capacity of three-phase squirrel-cage motor AC3(KW) |
380V |
660V |
380V |
660V |
CJX2-9 |
20 |
9 |
6.6 |
4 |
5.5 |
CJX2-12 |
20 |
12 |
8.9 |
5.5 |
7.5 |
CJX2-18 |
32 |
18 |
10.6 |
7.5 |
9 |
CJX2-25 |
40 |
25 |
18 |
11 |
15 |
CJX2-32 |
50 |
32 |
21 |
15 |
18.5 |
CJX2-40 |
60 |
40 |
34 |
18.5 |
30 |
CJX2-50 |
80 |
50 |
39 |
22 |
33 |
CJX2-65 |
80 |
65 |
42 |
30 |
37 |
CJX2-80 |
125 |
80 |
49 |
37 |
45 |
CJX2-95 |
125 |
95 |
49 |
45 |
55 |
Type |
Rated heat current (A) |
Rated working current (A) |
AC3 capacity of three-phase squirrel-cage motor AC3(KW) |
380V |
660V |
220V |
380V |
660V |
CJX2-F115 |
200 |
115 |
65 |
30 |
55 |
80 |
CJX2-F150 |
220 |
150 |
80 |
40 |
75 |
100 |
CJX2-F185 |
275 |
185 |
95 |
55 |
90 |
110 |
CJX2-F225 |
315 |
225 |
115 |
68 |
110 |
129 |
CJX2-F265 |
350 |
265 |
150 |
75 |
132 |
160 |
CJX2-F330 |
400 |
330 |
185 |
100 |
165 |
220 |
CJX2-F400 |
500 |
400 |
225 |
115 |
200 |
280 |
CJX2-F500 |
700 |
500 |
265 |
147 |
250 |
335 |
CJX2-F630 |
1000 |
630 |
335 |
200 |
335 |
450 |
CJX2-F780 |
1500 |
780 |
450 |
220 |
400 |
475 |
Type |
Rated heat current (A) |
Rated working current (A) |
AC3 capacity of three-phase squirrel-cage motor AC3(KW) |
220V |
380V |
660V |
CJX2-N09 |
20 |
9 |
2.2 |
4 |
5.5 |
CJX2-N12 |
20 |
12 |
3 |
5.5 |
7.5 |
CJX2-N18 |
32 |
18 |
4 |
7.5 |
10 |
CJX2-N25 |
40 |
25 |
5.5 |
11 |
15 |
CJX2-N32 |
50 |
32 |
7.5 |
15 |
18.5 |
CJX2-N38 |
50 |
38 |
9 |
18.5 |
18.5 |
CJX2-N40 |
60 |
40 |
11 |
18.5 |
30 |
CJX2-N50 |
80 |
50 |
15 |
22 |
33 |
CJX2-N65 |
80 |
65 |
18.5 |
30 |
37 |
CJX2-N80 |
125 |
80 |
22 |
37 |
45 |
CJX2-N95 |
125 |
95 |
25 |
45 |
45 |
Type |
Rated current AC3 Ue≤440V |
Rate heating current AC10≤40° |
Rated power AC3 3-phase motor 0≤40° |
Rated power AC4 3-phase motor 0<40° |
220/240V |
380/400V |
400V |
500V |
600/690V |
1000V |
200/230V |
380/400V |
440V |
500V |
A |
A |
KW |
KW |
KW |
KW |
KW |
KW |
KW |
KW |
KW |
KW |
CJX2-D115 |
115 |
200 |
30 |
55 |
59 |
75 |
80 |
75 |
9 |
18.5 |
18.5 |
30 |
CJX2-D150 |
150 |
250 |
40 |
75 |
80 |
90 |
100 |
90 |
11 |
22 |
22 |
37 |
CJX2-D170 |
170 |
250 |
55 |
90 |
100 |
110 |
110 |
100 |
22 |
40 |
45 |
51 |
CJX2-D205 |
205 |
275 |
63 |
110 |
110 |
120 |
129 |
100 |
25 |
45 |
51 |
59 |
CJX2-D245 |
245 |
315 |
75 |
132 |
132 |
160 |
160 |
147 |
30 |
55 |
63 |
75 |
CJX2-D300 |
300 |
400 |
100 |
160 |
200 |
200 |
220 |
160 |
37 |
63 |
75 |
80 |
CJX2-D410 |
410 |
500 |
110 |
220 |
250 |
250 |
280 |
185 |
40 |
75 |
80 |
90 |
CJX2-D475 |
475 |
700 |
147 |
265 |
280 |
335 |
335 |
335 |
45 |
80 |
100 |
110 |
CJX2-D620 |
620 |
1000 |
200 |
335 |
400 |
400 |
450 |
450 |
55 |
100 |
110 |
132 |
Matching coil volts
Voltage volts |
24 |
42 |
48 |
110 |
220 |
230 |
240 |
380 |
400 |
415 |
440 |
500 |
660 |
50HZ |
B5 |
D5 |
E5 |
F5 |
M5 |
P5 |
U5 |
Q5 |
V5 |
N5 |
R5 |
S5 |
Y5 |
60HZ |
B6 |
D6 |
E6 |
F6 |
M6 |
- |
U6 |
Q6 |
- |
- |
R6 |
- |
- |
50/60HZ |
B7 |
D7 |
E7 |
F7 |
M7 |
P7 |
U7 |
Q7 |
V7 |
N7 |
R7 |
- |
- |
CE